Paper Reading AI Learner

The Effect of Quantization on Clinical Benchmarks: Accuracy and Safety Across Model Families

2026-09-02 08:18:53
Leonard Twagirayezu, Prasenjit Mitra

Abstract

Quantization enables deployment of large language models on resource-constrained clinical edge devices, but its effect on clinical accuracy and safety remains understudied. We evaluate five 7-8B parameter models at FP16, GPTQ-INT8, and GPTQ-INT4 precision across five benchmarks: MedQA, MedMCQA, Med-HALT, a risk-stratified sample of HealthBench, and MedSafetyBench. The study jointly varies quantization bit width, model family, and clinical task type, with explicit risk stratification and safety measures. INT8 GPTQ is universally safe (max. degradation -1.9%-1.9%), while INT4 degradation is substantial and model-dependent: BioMistral-7B, clinically fine-tuned, loses 19.7% on MedMCQA, more than any general-purpose model, showing clinical fine-tuning does not confer compression robustness. MedMCQA degrades more than MedQA under INT4; Med-HALT is largely unaffected. On HealthBench's emergency-risk subgroup, Qwen2.5-7B degrades by 26.8% under INT4, suggesting high-risk scenarios are disproportionately vulnerable to compression. On MedSafetyBench, the model family dominates over precision (refusal rates range 10.2%-74.9% at FP16), though Qwen2.5-7B (-17.8%) and Meditron-7B (-28.3%) show substantial INT4 safety degradation; notably, Qwen2.5-7B is simultaneously the most accuracy-robust model, demonstrating that accuracy and safety robustness are independent properties. We additionally test two recovery methods, clinical calibration substitution and QLoRA fine-tuning, both producing the same trade-off: MedMCQA recovers while MedQA further degrades, indicating recovery strategies require task-specific validation rather than being assumed universally beneficial. These findings indicate INT8 is broadly safe for clinical deployment, while INT4 safety must be assessed per-model and per-task, and that safety alignment is determined primarily by instruction tuning rather than clinical domain adaptation.

Abstract (translated)

URL

https://arxiv.org/abs/2609.22216

PDF

https://arxiv.org/pdf/2609.22216.pdf


Tags
3D Action Action_Localization Action_Recognition Activity Adversarial Agent Attention Autonomous Bert Boundary_Detection Caption Chat Classification CNN Compressive_Sensing Contour Contrastive_Learning Deep_Learning Denoising Detection Dialog Diffusion Drone Dynamic_Memory_Network Edge_Detection Embedding Embodied Emotion Enhancement Face Face_Detection Face_Recognition Facial_Landmark Few-Shot Gait_Recognition GAN Gaze_Estimation Gesture Gradient_Descent Handwriting Human_Parsing Image_Caption Image_Classification Image_Compression Image_Enhancement Image_Generation Image_Matting Image_Retrieval Inference Inpainting Intelligent_Chip Knowledge Knowledge_Graph Language_Model LLM Matching Medical Memory_Networks Multi_Modal Multi_Task NAS NMT Object_Detection Object_Tracking OCR Ontology Optical_Character Optical_Flow Optimization Person_Re-identification Point_Cloud Portrait_Generation Pose Pose_Estimation Prediction QA Quantitative Quantitative_Finance Quantization Re-identification Recognition Recommendation Reconstruction Regularization Reinforcement_Learning Relation Relation_Extraction Represenation Represenation_Learning Restoration Review RNN Robot Salient Scene_Classification Scene_Generation Scene_Parsing Scene_Text Segmentation Self-Supervised Semantic_Instance_Segmentation Semantic_Segmentation Semi_Global Semi_Supervised Sence_graph Sentiment Sentiment_Classification Sketch SLAM Sparse Speech Speech_Recognition Style_Transfer Summarization Super_Resolution Surveillance Survey Text_Classification Text_Generation Time_Series Tracking Transfer_Learning Transformer Unsupervised Video_Caption Video_Classification Video_Indexing Video_Prediction Video_Retrieval Visual_Relation VQA Weakly_Supervised Zero-Shot